Customization: | Available |
---|---|
Certification: | ISO, CE, CCC |
Fan Type: | Axial Fan with Wall Ring |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | Rated Voltage | Operating Voltage | Frequency | Current(A) | Speed(min-1) | Max. Input Power(W) | Sound Level(dB(A)) | Air Flow(m³/H) | Air Pressure(Pa) |
FG3G200-2AGN-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G200-2AGL-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGC-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGS-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G250-2AGN-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G250-2AGL-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGC-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGS-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G300-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G300-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FW3G300-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G350-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FW3G350-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G350-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FW3G350-2APC-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G400-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G400-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FW3G400-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G450-2APN-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G450-2APL-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FW3G450-2APF-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G500-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FW3G500-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APN-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-2APL-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FW3G500-2APF-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G500-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FW3G500-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G630-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FG3G630-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FW3G630-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |
HVAC
EC fans are extensively utilized in HVAC systems, particularly where the ability to control speed is crucial and minimizing noise is essential.
Cooling
EC fans, powered by brushless DC motors, seamlessly integrate the best features of AC and DC power systems.
Air Purification
Beyond intelligent control and energy efficiency, one of the prominent attributes of EC fans is their compact design.
Refrigeration
Energy efficiency is the paramount characteristic considered, particularly because evaporator fan motors operate continuously
throughout the day, 24/7.
Automotive equipment
The EC brushless motorized fans are adaptable for use in both thermal circuits of combustion engines and in electric vehicles.
Medical Equipment
With superior performance, efficient energy use, and low noise output, EC fans are highly preferred in the medical sector.
Domestic shipments are expedited with delivery in just 7 days. For our valued international clients, anticipate a shipping timeframe of approximately 12 days. Opening new ventures, we commit to launching within a remarkable 45 days post R&D, ensuring swift and efficient global reach.
Q1:What kind of payments do you support?
A1: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% before shipment