Type | Rated Voltage | Operating Voltage | Frequency | Current(A) | Speed(min-1) | Max. Input Power(W) | Sound Level(dB(A)) | Air Flow(m³/H) | Air Pressure(Pa) |
FG3G200-2AGN-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G200-2AGL-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGC-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGS-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G250-2AGN-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G250-2AGL-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGC-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGS-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G300-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G300-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FW3G300-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G350-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FW3G350-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G350-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FW3G350-2APC-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G400-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G400-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FW3G400-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G450-2APN-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G450-2APL-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FW3G450-2APF-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G500-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FW3G500-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APN-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-2APL-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FW3G500-2APF-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G500-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FW3G500-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G630-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FG3G630-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FW3G630-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |
HVAC
In the realm of HVAC systems, EC fans stand out as indispensable, particularly where precise speed control is paramount and minimizing noise is crucial.
Cooling
EC fans, powered by advanced brushless DC motors, seamlessly blend the strengths of both AC and DC power sources.
Air Purification
Beyond their smart control and impressive energy efficiency, EC fans boast a notably compact size, making them a standout choice.
Refrigeration
Energy efficiency remains a pivotal feature, given that evaporator fan motors operate continuously,
necessitating considerations for round-the-clock functionality,
as they tirelessly function 24/7.
Automotive equipment
EC brushless motorized fans find versatile application in automotive settings, serving both combustion engine thermal circuits and electric vehicles with equal efficacy.
Medical Equipment
In the medical industry, EC fans are esteemed for their high-performance metrics, superior energy efficiency,
and remarkably low noise levels, making them highly sought after.
For our esteemed domestic customers, we ensure swift delivery within just 7 days. For our valued international clients, enjoy timely shipping, typically around 12 days, with all new openings completed within a maximum of 45 days post-research and development phase.
Q1:What kind of payments do you support?
A1: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% before shipment