Customization: | Available |
---|---|
Certification: | ISO, CE, CCC |
Fan Type: | Axial Fan with Wall Ring |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | Rated Voltage | Operating Voltage | Frequency | Current(A) | Speed(min-1) | Max. Input Power(W) | Sound Level(dB(A)) | Air Flow(m³/H) | Air Pressure(Pa) |
FG3G200-2AGN-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G200-2AGL-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGC-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FW3G200-2AGS-70 | 230VAC | 184~270 | 50/60Hz | 0.31 | 3000 | 45 | 62 | 1205 | 250 |
FG3G250-2AGN-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G250-2AGL-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGC-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FW3G250-2AGS-90 | 230VAC | 184~270 | 50/60Hz | 0.6 | 2650 | 80 | 61 | 1740 | 226 |
FG3G300-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G300-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FW3G300-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.35 | 2300 | 170 | 64 | 3160 | 210 |
FG3G350-2APN-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APL-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FW3G350-2APC-90 | 230VAC | 184~270 | 50/60Hz | 1.15 | 1580 | 160 | 63 | 3500 | 135 |
FG3G350-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G350-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FW3G350-2APC-20 | 230VAC | 184~270 | 50/60Hz | 2.0 | 2000 | 460 | 80 | 4650 | 275 |
FG3G400-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G400-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FW3G400-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2.18 | 1760 | 500 | 79 | 5900 | 240 |
FG3G450-2APN-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G450-2APL-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FW3G450-2APF-20 | 230VAC | 184~270 | 50/60Hz | 1.9 | 1600 | 420 | 68 | 6150 | 250 |
FG3G500-2APN-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APL-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FW3G500-2APF-20 | 230VAC | 184~270 | 50/60Hz | 2 | 1250 | 450 | 71 | 6781 | 285 |
FG3G500-2APN-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-2APL-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FW3G500-2APF-30 | 230VAC | 184~270 | 50/60Hz | 3.1 | 1550 | 700 | 74 | 8750 | 250 |
FG3G500-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G500-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FW3G500-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.5 | 1680 | 850 | 78.4 | 10400 | 300 |
FG3G630-4APN-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FG3G630-4APL-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
FW3G630-4APF-31 | 380VAC | 304~456 | 50/60Hz | 1.3 | 1150 | 800 | 69 | 14500 | 240 |
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |
HVAC
EC fans are widely applied in advanced HVAC systems, especially in scenarios where precise speed control is required and noise reduction is paramount. These fans are indispensable for creating comfortable environments, ensuring optimal indoor air quality and energy efficiency.
Cooling
EC fans are essentially cutting-edge fans powered by a brushless DC motor, harmoniously merging the benefits of both AC and DC power sources. This combination offers superior cooling performance and energy efficiency, making them ideal for a wide range of cooling applications.
Air Purification
Beyond their intelligent control and exceptional energy-saving capabilities, the compact size of EC fans makes them a significant asset in air purification systems, ensuring clean air while occupying minimal space.
Refrigeration
Energy-saving is the paramount feature of EC fans, crucial for refrigeration applications where efficiency is key. Given that evaporator fan motors operate continuously, 24 hours a day, these fans dramatically reduce energy consumption while maintaining robust performance.
consideration because the evaporator fan motors run twenty four
hours a day.
Automotive equipment
The highly efficient EC brushless motorized fans are versatile and can be seamlessly integrated into both combustion engine thermal circuits and modern electric vehicles, enhancing thermal management and energy efficiency.
Medical Equipment
EC fans, renowned for their high performance, efficient energy consumption, and low noise level, are highly valued in the medical industry. They are essential for maintaining sterile environments and ensuring the reliability of sensitive medical equipment.
noise level,etc, are also favored in medical industry.
Domestic shipping is swift, with delivery times of just 7 days. For our international clients, you can expect your orders to arrive approximately 12 days after dispatch. Upon the initial unveiling of R&D, anticipate seamless product availability within 45 days.
Q1:What kind of payments do you support?
A1: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% before shipment